Sample Analysis

D86 Analysis

Sample Analysis

D86 Analysis


Measurement Principle 

TANAKA AD7S Distillation Test

(Based on ASTM D86 Standard)

1. The sample is introduced into the distillation flask and continuously distilled while measuring the vapor volume at each temperature point.
ㅤ -  Measurement units: °C (temperature), mL (volume)
2. The TANAKA AD7S equipment automatically measures the distillation curve.
 - Provides high accuracy and reproducibility
ㅤ - Complies with the ASTM D86 standard procedure


3. The distillation curve results are used to evaluate the boiling characteristics and quality of fuels and petroleum products. 


Measurement Items

 

Distillation Curve

- Volume change of distillate components according to the sample temperature
- Unit : °C, mL

 

Initial Boiling Point and Final Boiling Point

- Initial and final boiling point temperatures defined according to ASTM D86 standards

 

Other Conditions

- Accurate measurements performed following the ASTM D86 standard procedure

 

Results Provided

- Provides reproducible and precise distillation curves and boiling point results


Analysis Procedure

Submitting a Request for Analysis : Contact us via phone or email

Phone : 02-2043-1957

E-mail : snp0529@soletek.co.kr


- Fill out the analysis request form and send it via email or along with the sample by courier.

- Minimum required sample volume : 100ml

- Please send the samples in a sealed container (glass bottles are recommended).


- Address

ㅤBldg B, 2F, 4 Dongnam-ro 29-gil, Songpa-gu, Seoul 05721, South Korea (Soletek Trading Co., Ltd.)

- Use of TANAKA AD7S equipment

-  Automated distillation test performed in accordance with ASTM D86 standard procedure

- Results are provided in the company’s standard format.

- Please inquire in advance regarding analysis fees and scheduling.


Sample Preparation

1.  Standard Conditions

ㅤ- A minimum of 100 mL of the sample is required.

ㅤ- Samples should be sent in a sealed container (glass or plastic bottles are recommended).

 Precautions


- Ensure proper packaging to prevent sample leakage.

- It is recommended to inquire in advance to confirm that the sample's properties meet the analysis conditions.


Measurement Principle

TANAKA AD7S Distillation Test (Based on ASTM D86 Standard)

1. The sample is introduced into the distillation flask and continuously distilled while measuring the vapor volume at each temperature point.
ㅤ - Measurement units: °C (temperature), mL (volume)

2. The TANAKA AD7S equipment automatically measures the distillation curve.
ㅤ - Provides high accuracy and reproducibility
ㅤ - Complies with the ASTM D86 standard procedure

3. The distillation curve results are used to evaluate the boiling characteristics and quality of fuels and petroleum products. 


Measurement Items

ㅤDistillation Curve

- Volume change of distillate components according to the sample temperature
- Unit : °C, mL

ㅤInitial Boiling Point and Final Boiling Point

- Initial and final boiling point temperatures defined according to ASTM D86 standards

ㅤOther Conditions

- Accurate measurements performed following the ASTM D86 standard procedure

ㅤResults Provided

- Provides reproducible and precise distillation curves and boiling point results


Analysis Procedure

Submitting a Request for Analysis: Contact us via phone or email

Phone : 02-2043-1957

E-mail : snp0529@soletek.co.kr


- Fill out the analysis request form and send it via email or along with the sample by courier.

- Minimum required sample volume : 100ml

- Please send the samples in a sealed container (glass bottles are recommended).


- Address

Bldg B, 2F, 4 Dongnam-ro 29-gil, Songpa-gu, Seoul 05721, South Korea
 (Soletek Trading Co., Ltd.)

- Use of TANAKA AD7S equipment

- Automated distillation test performed in accordance with ASTM D86 standard procedure

- Results are provided in the company’s standard format.

- Please inquire in advance regarding analysis fees and scheduling.


Sample Preparation

1. Standard Conditions
ㅤ - A minimum of 100 mL of the sample is required.

ㅤ - Samples should be sent in a sealed container (glass or plastic bottles are recommended).

Precautions 


-  Ensure proper packaging to prevent sample leakage.
-  It is recommended to inquire in advance to confirm that the sample's properties meet the analysis conditions.

Soletek Trading Co., Ltd. 

Owner : Junseop Yoon

Address : 2F B-dong, 4 Dongnam-ro 29-gil, Songpa-gu, Seoul, 05721 Korea

Business registration number : 215-87-33254

Number : +82-2-2043-1957 

E-mail : info@soletek.co.kr

Copyright ⓒ SOLETEK TRADING co., LTD All Rights Reserved.

Soletek Trading Co., Ltd.|Owner : Junseop Yoon

Address : 2F B-dong, 4 Dongnam-ro 29-gil, Songpa-gu, Seoul, 05721 Korea

 Business registration number : 215-87-33254|Number : +82-2-2043-1957|E-mail : info@soletek.co.kr

Copyright ⓒ SOLETEK TRADING co., LTD All Rights Reserved.