Measurement Principle 

TANAKA MPC-6 Automatic Pour Point and Cloud Point Measurement 

(Based on ASTM D6749 and ASTM D7683 Standards)

1. The sample is introduced into a sealed sample chamber, and the temperature is gradually adjusted to automatically measure the pour point and cloud point.
ㅤ - Measurement unit : °C

2. The TANAKA MPC-6 device is used to automatically measure pour point and cloud point.
 - Enables quick and accurate measurement with a small sample volume (4.5 mL).
ㅤ - Adheres to ASTM D6749 and ASTM D7683 standard procedures.


3. Pour point and cloud point results are used to evaluate the low-temperature properties of fuels and lubricants.


Measurement Items

 

Pour Point

- The lowest temperature at which the sample loses fluidity.
- Unit : °C

 

Cloud Point

- The temperature at which the sample begins to turn cloudy upon cooling.
- Unit : °C

 

Other Conditions

- Accurate measurements are performed in compliance with ASTM D6749 and ASTM D7683 standard procedures.

 

Results Provided

- Accurate pour point and cloud point results.


Analysis Procedure

Submitting a Request for Analysis

: Contact us via phone or email

Phone : 02-2043-1957

E-mail : snp0529@soletek.co.kr


- Fill out the analysis request form and send it via email or along with the sample by courier.

- Minimum required sample volume : 4.5ml

- Please send the samples in a sealed container (glass bottles are recommended).


- Address

ㅤBldg B, 2F, 4 Dongnam-ro 29-gil, Songpa-gu, Seoul 05721, South Korea (Soletek Trading Co., Ltd.)

- The TANAKA MPC-6 device is used.

- Automated pour point and cloud point measurements are conducted in accordance with ASTM D6749 and ASTM D7683 standard procedures.

- Results are provided in the company’s standard format.

- Please inquire in advance regarding analysis fees and scheduling.


Sample Preparation

1.  Standard Conditions

ㅤ- A minimum of 4.5 mL of the sample is required.

ㅤ- Samples should be sent in a sealed container (glass or plastic bottles are recommended).

 Precautions


- Ensure proper packaging to prevent sample leakage.

- It is recommended to inquire in advance to confirm that the sample's properties meet the analysis conditions.


Measurement Principle

TANAKA MPC-6 Automatic Pour Point and Cloud Point Measurement 

(Based on ASTM D6749 and ASTM D7683 Standards)

1. The sample is introduced into a sealed sample chamber, and the temperature is gradually adjusted to automatically measure the pour point and cloud point.
ㅤ - Measurement unit: °C

2. The TANAKA MPC-6 device is used to automatically measure pour point and cloud point.
ㅤ - Enables quick and accurate measurement with a small sample volume (4.5 mL).
ㅤ - Adheres to ASTM D6749 and ASTM D7683 standard procedures.

3. Pour point and cloud point results are used to evaluate the low-temperature properties of fuels and lubricants.


Measurement Items

ㅤPour Point

- The lowest temperature at which the sample loses fluidity.
- Unit : °C

ㅤCloud Point

- The temperature at which the sample begins to turn cloudy upon cooling.
- Unit : °C

ㅤOther Conditions

- Accurate measurements are performed in compliance with ASTM D6749 and ASTM D7683 standard procedures.

ㅤResults Provided

- Accurate pour point and cloud point results.


Analysis Procedure

Submitting a Request for Analysis : Contact us via phone or email

Phone : 02-2043-1957

E-mail : snp0529@soletek.co.kr


- Fill out the analysis request form and send it via email or along with the sample by courier.

- Minimum required sample volume : 4.5ml

- Please send the samples in a sealed container (glass bottles are recommended).


- Address

Bldg B, 2F, 4 Dongnam-ro 29-gil, Songpa-gu, Seoul 05721, South Korea
 (Soletek Trading Co., Ltd.)

- The TANAKA MPC-6 device is used.

- Automated pour point and cloud point measurements are conducted in accordance with ASTM D6749 and ASTM D7683 standard procedures.

- Results are provided in the company’s standard format.

- Please inquire in advance regarding analysis fees and scheduling.


Sample Preparation

1. Standard Conditions
ㅤ - A minimum of 4.5 mL of the sample is required.

ㅤ - Samples should be sent in a sealed container (glass or plastic bottles are recommended).

Precautions


- Ensure proper packaging to prevent sample leakage.

- It is recommended to inquire in advance to confirm that the sample's properties meet the analysis conditions.

Soletek Trading Co., Ltd. 

Owner : Junseop Yoon

Address : 2F B-dong, 4 Dongnam-ro 29-gil, Songpa-gu, Seoul, 05721 Korea

Business registration number : 215-87-33254

Number : +82-2-2043-1957 

E-mail : info@soletek.co.kr

Copyright ⓒ SOLETEK TRADING co., LTD All Rights Reserved.

Soletek Trading Co., Ltd.|Owner : Junseop Yoon

Address : 2F B-dong, 4 Dongnam-ro 29-gil, Songpa-gu, Seoul, 05721 Korea

 Business registration number : 215-87-33254|Number : +82-2-2043-1957|E-mail : info@soletek.co.kr

Copyright ⓒ SOLETEK TRADING co., LTD All Rights Reserved.