Measurement Principle
TANAKA MPC-6 Automatic Pour Point and Cloud Point Measurement
(Based on ASTM D6749 and ASTM D7683 Standards)
1. The sample is introduced into a sealed sample chamber, and the temperature is gradually adjusted to automatically measure the pour point and cloud point.
ㅤ - Measurement unit : °C
2. The TANAKA MPC-6 device is used to automatically measure pour point and cloud point.
ㅤ - Enables quick and accurate measurement with a small sample volume (4.5 mL).
ㅤ - Adheres to ASTM D6749 and ASTM D7683 standard procedures.
3. Pour point and cloud point results are used to evaluate the low-temperature properties of fuels and lubricants.
Measurement Items
Pour Point
- The lowest temperature at which the sample loses fluidity.
- Unit : °C
Cloud Point
- The temperature at which the sample begins to turn cloudy upon cooling.
- Unit : °C
Other Conditions
- Accurate measurements are performed in compliance with ASTM D6749 and ASTM D7683 standard procedures.
Results Provided
- Accurate pour point and cloud point results.
Analysis Procedure
Submitting a Request for Analysis
: Contact us via phone or email
Phone : 02-2043-1957
E-mail : snp0529@soletek.co.kr
- Fill out the analysis request form and send it via email or along with the sample by courier.
- Minimum required sample volume : 4.5ml
- Please send the samples in a sealed container (glass bottles are recommended).
- Address
ㅤBldg B, 2F, 4 Dongnam-ro 29-gil, Songpa-gu, Seoul 05721, South Korea (Soletek Trading Co., Ltd.)
- The TANAKA MPC-6 device is used.
- Automated pour point and cloud point measurements are conducted in accordance with ASTM D6749 and ASTM D7683 standard procedures.
- Results are provided in the company’s standard format.
- Please inquire in advance regarding analysis fees and scheduling.
Sample Preparation
1. Standard Conditions
ㅤ- A minimum of 4.5 mL of the sample is required.
ㅤ- Samples should be sent in a sealed container (glass or plastic bottles are recommended).
Precautions
- Ensure proper packaging to prevent sample leakage.
- It is recommended to inquire in advance to confirm that the sample's properties meet the analysis conditions.
Measurement Principle
TANAKA MPC-6 Automatic Pour Point and Cloud Point Measurement
(Based on ASTM D6749 and ASTM D7683 Standards)
1. The sample is introduced into a sealed sample chamber, and the temperature is gradually adjusted to automatically measure the pour point and cloud point.
ㅤ - Measurement unit: °C
2. The TANAKA MPC-6 device is used to automatically measure pour point and cloud point.
ㅤ - Enables quick and accurate measurement with a small sample volume (4.5 mL).
ㅤ - Adheres to ASTM D6749 and ASTM D7683 standard procedures.
3. Pour point and cloud point results are used to evaluate the low-temperature properties of fuels and lubricants.
Measurement Items
ㅤPour Point
- The lowest temperature at which the sample loses fluidity.
- Unit : °C
ㅤCloud Point
- The temperature at which the sample begins to turn cloudy upon cooling.
- Unit : °C
ㅤOther Conditions
- Accurate measurements are performed in compliance with ASTM D6749 and ASTM D7683 standard procedures.
ㅤResults Provided
- Accurate pour point and cloud point results.
Analysis Procedure
Submitting a Request for Analysis : Contact us via phone or email
Phone : 02-2043-1957
E-mail : snp0529@soletek.co.kr
- Fill out the analysis request form and send it via email or along with the sample by courier.
- Minimum required sample volume : 4.5ml
- Please send the samples in a sealed container (glass bottles are recommended).
- Address
ㅤBldg B, 2F, 4 Dongnam-ro 29-gil, Songpa-gu, Seoul 05721, South Korea
(Soletek Trading Co., Ltd.)
- The TANAKA MPC-6 device is used.
- Automated pour point and cloud point measurements are conducted in accordance with ASTM D6749 and ASTM D7683 standard procedures.
- Results are provided in the company’s standard format.
- Please inquire in advance regarding analysis fees and scheduling.
Sample Preparation
1. Standard Conditions
ㅤ - A minimum of 4.5 mL of the sample is required.
ㅤ - Samples should be sent in a sealed container (glass or plastic bottles are recommended).
Precautions
- Ensure proper packaging to prevent sample leakage.
- It is recommended to inquire in advance to confirm that the sample's properties meet the analysis conditions.
Soletek Trading Co., Ltd.
Owner : Junseop Yoon
Address : 2F B-dong, 4 Dongnam-ro 29-gil, Songpa-gu, Seoul, 05721 Korea
Business registration number : 215-87-33254
Number : +82-2-2043-1957
E-mail : info@soletek.co.kr
Copyright ⓒ SOLETEK TRADING co., LTD All Rights Reserved.
Soletek Trading Co., Ltd.|Owner : Junseop Yoon
Address : 2F B-dong, 4 Dongnam-ro 29-gil, Songpa-gu, Seoul, 05721 Korea
Business registration number : 215-87-33254|Number : +82-2-2043-1957|E-mail : info@soletek.co.kr
Copyright ⓒ SOLETEK TRADING co., LTD All Rights Reserved.